Part Number Hot Search : 
20B1TR USB22 AS002M24 F2015 00102 SR850 BCPZRL 40007
Product Description
Full Text Search
 

To Download 2957-1500 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 rectangular, multiple-position rack/panel insulation displacement connectors (idc) qr/p18 series overview the qr/p18 series of miniature rack/panel connectors is designed for the complete segmentation of the structure of the external holder/terminal units of the well-received qr/p series of plug-in rectangular rack/panel connectors; furthermore, the subsequent insertion of the harnessed terminal unit affords a more efficient harness mounting task. these connectors are configured with 12, 18, or 24 (insulation displacement connection) positions in the signal portion, and 4 (crimp) positions in the power supply portion. features 1. completely segmented structure of the external holder/terminal unit in order to improve the harness mounting task, the connectors are designed for the complete segmentation of the external holder and the signal/power supply unit, and the method of subsequently inserting harnessed products aims to improve the workability of the power supply/signal section harness as well as the mounting of the set. 2. signal unit the signal unit uses the highly reliable insulation displacement connection method. (the wire is awg #26 and the insulation outside diameter is 0.88 mm.) the insulation displacement task can now be used by fitting a special applicator to a commercially available automatic insulation displacement machine, or a manual press can also be selected. 3. power supply portion the power supply terminals permit the use of a crimp harness using wire of awg #16 to 18 (and insulation outside diameter of 2.1 to 2.2 mm), and can accommodate a maximum of 12 a. 4. sequenced structure connectors possess two sequenced contacts in the signal male unit and one sequenced contact in the power supply female unit making them perfect in terms of safety too. 5. panel installation installation to a panel uses a single-action method on the anchored side and a floating screw structure on the floating side which permits smooth insertion and disconnection without forcing. 6. rohs compliant all components and materials comply with the requirements of the eu directive 2002/95/ec. * a portion of this series is suitably constructed for high-speed differential transfer, and using a suitable cable, transfer of 2.5gbps per pair is possible. 2007.4 external holder power supply contact male unit power supply contact female unit power supply male contacts power supply female contacts signal contact male unit signal contact female unit panel 2.5gbps awg28 2m scale x : 100psec/div y : 100v/div 2.5 gbps eye pattern waveform applications ppc, transmitting and receiving devices, data communications equipment, vending machines, measuring instruments, factory automation equipment, and other high- speed transfer applications, etc. the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
2 product specifications materials ratings voltage rating current rating 125 v ac (signal contacts) 300v ac (power contacts) 1a (signal contacts) 12a (power contacts) operating temperature range -40? to +105? (note 1) products external holder signal contact unit power contact unit power supply contacts insulator insulator female contacts male contacts insulator female contacts male contacts female contacts male contacts pbt pa phosphor bronze phosphor bronze pbt phosphor bronze phosphor bronze copper alloy copper alloy --------------- --------------- gold plated gold plated --------------- gold plated gold plated gold plated + tin copper plated gold plated + tin copper plated ul94v-0 ul94v-0 --------------- -------------- ul94v-0 -------------- -------------- -------------- -------------- remarks finish components material 100 ma 500 v dc 500 v ac / one minute frequency: 10 to 55 hz, single amplitude of 0.75 mm, 2 hours in each of the 3 axis. acceleration of 490 m/s 2 , 11 ms duration, sine half-wave waveform, 3 cycles in each of the 3 axis temperature: -55? +5? to +35? +105? +5? to +35? time: 30 5 30 5 (minutes) 5 cycles 96 hours at 40? and rh 90% to 95% 5% salt water solution for 48 hours item 3. withstanding voltage 4. durability (mating / un-mating) 5. vibration 6. shock 7. temperature cycle 8. humidity (steady state) 9. salt mist specification 50m? max. (signal contacts) (note 2) 10m? max. (power contacts) (note 2) 1000m? min. (signal contacts) 5000m? min. (power contacts) no flashover or insulation breakdown. contact resistance: 70m? max. (signal contacts) 20m? max. (power contacts) 3000 cycles contact resistance: 70m? max. (signal contacts) 20m? max. (power contacts) no damage, cracks, or parts dislocation. insulation resistance: 100m ? min. (signal contacts, state) 3000m ? min. (power contacts, state) no damage, cracks, or parts dislocation. no corrosions. no electrical discontinuity of 10s or more. no damage, cracks, or parts dislocation. conditions 1. contact resistance 2. insulation resistance note1: includes temperature rise caused by current flow. note2: excludes wire conductor resistance. function diagram power supply/signal combination type signal type qr/p18-p4s qr/p18-s4s- qr/p18-4p-c qr/p18-4s-c qr/p17-pca-11(50) qr/p17-sca-11(50) qr/p18-p qr/p18-s qr/p18-p qr/p18-s qr/p18-s qr/p18-p the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
3 ordering information external holder. signal contact termination block power contact insert power contact series name signal contact type s: female contact p: male contact power contact type s: female contact p: male contact applicable panel thickness a: 2mm b: 1.5mm number of signal contact of external holder a: 12 pos. (contact pitch 1.5mm) b: 18 pos. (contact pitch 1.5mm) c: 24 pos. (contact pitch 1.5mm) number of power contact 1 4 6 5 2 3 qr / p18 - s a 4 p - a 1 2 6 3 5 4 series name signal contact type s: female contact p: male contact number of signal contact of signal contact termination block a: 12 pos. (contact pitch 1.5mm) b: 18 pos. (contact pitch 1.5mm) c: 24 pos. (contact pitch 1.5mm) number of signal contact 1 4 2 3 qr / p18 - 12 s a 1 2 3 4 series name power contact type s: female contact p: male contact connector type c: crimp housing number of power contact 1 4 2 3 qr / p18 - 4 p - c 1 2 3 4 series name power contact type pc: male crimp contact sc: female crimp contact applicable wire 1: awg#16 to 18 contact plating 1: gold plated applicable wire style a: ul1015 packaging 1: pack packaging 2: reel packaging 1 4 6 5 2 3 qr / p17 - pc a - 1 1 1 1 2 6 3 5 4 the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
4 external holder 6-r0.5 0 -0.2 a 18.8 b 20.7 +0.1 0 19.8 +0.1 0 14.750.05 d +0.1 0 c0.1 2-r0.3 +0.2 0 10.50.1 13.9 +0.1 0 2-m30.5 10.5 (2) 3 23 32.65 26.5 die roll side should be connector mating side. 2 6.15 23 26.5 2.5 2 5.1 29 7.4 qr/p18-s4p-a qr/p18-p4s qr/p15-screw panel panel female power contact, male signal contact type panel cutout mated condition (shown for reference) note: establish panel mounting so that the mating gap dimensions of the power supply side and the signal side are 1.5 mm or less. applicable panel thickness: 2.0mm part number qr/p18-pa4s qr/p18-pb4s qr/p18-pc4s cl no. cl221-0293-8 cl221-0313-3 cl221-0297-9 number of contacts power 4 4 4 signal 12 18 24 a 54.65 58.65 63.15 b 46.25 50.25 54.75 c 46.25 50.25 54.75 d rohs 27.2 31.2 35.7 yes panel attachment screw (qr/p15-screw cl221-0251-8) is optional. the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
5 6-r0.5 0 -0.2 a 18.8 b 20.7 +0.1 0 19.8 +0.1 0 14.750.05 d +0.1 0 c0.1 2-r0.3 +0.2 0 10.50.1 13.9 +0.1 0 2-m30.5 10.5 (2) 3 23 32.65 26.5 die roll side should be connector mating side. male power contact, female signal contact type panel cutout applicable panel thickness: 2.0mm part number qr/p18-sa4p-a qr/p18-sb4p-a qr/p18-sc4p-a cl no. cl221-0294-0 cl221-0315-9 cl221-0298-1 number of contacts power 4 4 4 signal 12 18 24 a 43.85 47.85 52.35 b 37.9 41.9 46.4 c 27.25 31.25 35.75 d rohs 17.3 21.3 25.8 yes the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
6 external holder (signal type) 13 a 18 3 15 b 4.7 4.70.1 (15) t=1.5 die roll side should be connector mating side. 14.8 +0.2 0 5-r0.5m ax. 2.2 0 -0.2 d +0.2 0 e0.1 c +0.2 0 r0.3min. 2-m30.5 17.5 1.5 7.4 2.5 15 1.5 5.1 qr/p15-screw qr/p18-p qr/p18-s-b panel 3 male signal contact type panel cutout mated condition (shown for reference) note: establish panel mounting so that the mating gap dimensions of the power supply side and the signal side are 1.5 mm or less. applicable panel thickness: 1.5mm part number qr/p18-pb qr/p18-pc cl no. cl221-0309-6 cl221-0311-8 number of contacts signal 18 24 b a 29.5 34.0 37.7 42.2 c 27.0 31.5 d 23.5 28.0 e rohs 29.5 34.0 yes panel attachment screw (qr/p15-screw cl221-0251-8) is optional. the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
7 13 a 18 3 15 b 4.7 4.70.1 (15) t=1.5 die roll side should be connector mating side. 14.8 +0.2 0 5-r0.5m ax. 2.2 0 -0.2 d +0.2 0 e0.1 c +0.2 0 r0.3min. 2-m30.5 female signal contact type panel cutout applicable panel thickness: 1.5mm part number qr/p18-sb-b qr/p18-sc-b cl no. cl221-0310-5 cl221-0312-0 number of contacts signal 18 24 a 28.05 32.55 b 25.1 29.6 c 13 .00 15.25 d rohs 0 7.3 11.8 yes the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
8 15 a b sequence contact sequence contact male, contact pitch 1.5mm cl no. cl221-0291-2 cl221-0285-0 cl221-0295-3 part number qr/p18-12pa qr/p18-18pb qr/p18-24pc number of contacts 13.5 17.5 22 .0 12 18 24 b rohs a 14 .0 18 .0 22.5 yes adscable cable: awg#26, insulator diameter 0.88mm cl no. cl221-0292-5 cl221-0286-2 cl221-0296-6 part number qr/p18-12sa qr/p18-18sb qr/p18-24sc number of contacts 13.5 17.5 22 .0 12 18 24 b rohs a 14 .0 18 .0 22.5 yes applicable cable: awg#26, insulator diameter 0.88mm 15 a b female, contact pitch 1.5mm signal contact termination block the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
9 female male power contact insert 31.1 17.9 15.9 part number qr/p18-4p-c cl no. rohs cl221-0316-1 yes sequence contact(no.4) 27.7 16.2 13.5 part number qr/p18-4s-c cl no. rohs cl221-0314-6 yes the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
10 3 28.5 applicable wire size 16-18 applicable cable awg16~18 ul1015 awg16~18 ul1015 cl no. cl221-0265-2-50 cl221-0263-7-50 bag reel part number qr/p17-pca-111(50) qr/p17-pca-211(50) q'ty rohs packaging 100 3000 yes applicable cable: awg#16 to 18, insulator diameter 2.1mm to 3.2mm applicable wire size 4 18.3 16-18 female contact applicable cable awg16~18 ul1015 awg16~18 ul1015 cl no. cl221-0264-0-50 cl221-0262-4-50 bag reel q'ty rohs packaging 100 3000 yes applicable cable: awg#16 to 18, insulator diameter 2.1mm to 3.2mm part number qr/p17-sca-111(50) qr/p17-sca-211(50) male contact power contact the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
11 power contact crimp tool signal contact termination block idc tool b tools ) f

% $ f

 $ f

%& $ + *41 

  + *41 

   + *41  'b
)$!e$!@b0(  " $ 
"
%*41b *41b %&*41b %56g000 %56g600 + "  
%+ %+ c c %&1 %&1 %+ c %&1 %+ c %&1 ) f + " 
 
   + 
  2
  
"
f 0&g +06g +06g 1b06 g 1 + "  g1+'60( g1+'60( g1+%'60( g1+%'60( g1+%'60( g1+%'60( g1+'60( g1+'60( g1+%'60( g1+%'60( the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.
12 the contents of this catalog are current as of date of publication. contents are subject to change without notice for the purpo se of improvements. 5-23,osaki 5-chome,shinagawa-ku,tokyo 141-8587,japan phone: 81-3-3491-9741, fax: 81-3-3493-2933 http://www.hirose.com http://www.hirose-connectors.com 2.550.1 2.080.1 insulation displacement height aa cable 0 ~0.5 cable end position a-a signal contact unit (male) signal contact unit (female) b b cable 0 ~0.5 cable end position b-b 2.550.1 2.080.1 insulation displacement height insulation height insulation height power supply contacts cable spring 1.6 mm or greater male contact cable female contact spring 3.6 mm or greater (1) after wiring the cable, examine the cable end position, the insulation displacement height, and the insulation height. (2) in examining the insulation displacement height and the insulation height, use a measurement pin having a tip of 0.5 mm diamete r. (3) for information about the detailed inspection method, please request the "inspection standards manual" from hirose electric. (4) the inspection method of the diagrams is for cable with awg #26 wire and an insulation outside diameter of 0.88 mm. before inserting the power supply contacts into the power supply terminal unit, check that the spring portion illustrated in th e diagram is not misshapen. when the spring portion is less than the dimensions indicated in the diagram, the spring could pull out from the power supply terminal unit; therefore, the specified dimensions should be maintained. signal contact unit inspection after cable wiring the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information. all non-rohs products have been discontinued, or will be discontinued soon. please check the products status on the hirose website rohs search at www.hirose-connectors.com, or contact your hirose sales representative.


▲Up To Search▲   

 
Price & Availability of 2957-1500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X